Analog Timer
- Simple set up method
- Free power (24-240 V a.c/d.c)
- Repeated operation of 0.3% of maximum range
- Selection of time unit (3 kinds) due to front side of deep switch
Model |
Exposure type (E) |
T48N |
Panel type (P) |
Function |
POWER ON DELAY TIMER |
Size |
Exposure type (E) |
40.5(W) 50.5(H) |
Panel type (P) |
Power supply |
24-240 V a.c 50/60Hz, 24-240 V d.c ( ±10 %) |
Power Consumption |
Max. 4.5 V A (at 240 V a.c 60 Hz ), Max. 1.5 W (at 24 V d.c ) |
Return time |
Max. 100 ms |
Maximum |
01 |
0.01 ~ 1 s / 0.01 ~ 1 m / 0.01 ~ 1 h |
03 |
0.01 ~ 3 s / 0.01 ~ 3 m / 0.01 ~ 3 h |
06 |
0.01 ~ 6 s / 0.01 ~ 6 m / 0.01 ~ 6 h |
10 |
0.01 ~ 10 s / 0.01 ~ 10 m / 0.01 ~ 10 h |
30 |
0.01 ~ 30 s / 0.01 ~ 30 m / 0.01 ~ 30 h |
60 |
0.01 ~ 60 s / 0.01 ~ 60 m / 0.01 ~ 60 h |
12H |
0.01 ~ 12 h / 0.01 ~ 24 h / 0.01~ 48 h (For 24 hours 'x2' and for 48 hours 'x4' ) |
Accuracy |
Repeat error |
Max. 0.3 % (ratio of Max. scale) |
Setting error |
Max. 5 % (ratio of Max. scale) |
Voltage error |
Max. 0.5 % |
Temperature error |
Max. 2 % |
Control output |
Output mode |
POWER ON DELAY |
Contact construction |
A type (On-delay 1c + Constant contact 1a) / |
B type (On-delay 1c + Constant contact 1c) / C type(On-delay 2c) |
|
Capacity |
250 V a.c 3 A Resistive load |
Life span of relay |
Mechanical : 10 million times / Electrical : 100,000 times |
Dielectric strength |
2000 V a.c 50 / 60 Hz for 1 minute |
Noise |
± 2 kV |
Insulation resistance |
Min. 100 MΩ (500 V d.c mega standard) |
Vibration |
Durability |
10-55 Hz (cycle 1 minute), Double amplitude 0.5 mm for 2h. |
Malfunction |
10-55 Hz (cycle 1 minute), Double amplitude 0.5 mm for 10m. |
Shock |
Durability |
300 m/s² (30 G) X Y Z each direction 3 times |
Malfunction |
100 m/s² (10 G) X Y Z each direction 3 times |
Ambient temperature |
-10 ~ 55 °C Without freezing |
Storage temperature |
-25 ~ 65 °C Without freezing |
Ambient humidity |
30 ~ 85 % R.H. |
Certification |
CE approval (except TF62D Series) |
Model |
Suffix code |
Description |
Model |
|
|
|
|
Analog Timer |
T38N |
- |
- |
|
40.5(W) x 50.5(H)mm(Applied to adapter for panel) |
|
T48N |
|
|
|
48.0(W) x 48.0(H)mm |
T57N |
|
|
|
'E' Size - 50.0(W) x 62.0(H)mm |
'P' Size - 57.5(W) x 84.5(H)mm |
|
TF62N |
|
|
|
TF62D |
|
|
|
Fixture type |
E |
|
|
Exposure type |
P |
|
|
Panel type |
Maximum time |
01 |
|
1 sec / 1 min / 1 hour |
03 |
|
3 sec / 3 min / 3 hour |
06 |
|
6 sec / 6 min / 6 hour |
10 |
|
10 sec / 10 min / 10 hour |
30 |
|
30 sec / 30 min / 30 hour |
60 |
|
60 sec / 60 min / 60 hour |
12H |
|
12 hour / 24 hour / 48 hour(exceptT57N/TF62N) |
Control output |
A |
On-delay 1c+Constant 1a (For T38N / T48N / T57N ) |
B |
On-delay 1c+Constant 1c (For T38N / T48N / T57N ) |
C |
Constant 2c (For T38N / T48N / T57N) |
D |
Constant 1c (For TF62N ) |
F |
Constant 1c (For TF62D ) |