Operate on any voltage from AC 85~265V at 50/60Hz.
DC 24V is also available (optional function)
IP65 Proof
IP66(NEMA4) dust & water proof is available for all models(optional function)
Heater Break Alarm(HBA)
Heater current flowing through CT can be displayed on controller If heater current is less than HBA set value. AL1will be activated(optional function)
MODBUS Communcation
FY series suport both MODBUS RTU and MODBUS ASCII protocal. Communication between controller and HMIa or other equipment is more conveniet(optional function)
Autotuning(AT)
AT Function can calculate the optimize PID value for your control system,without trying and error manually.
Auto/Manual mode
Conveniently switched between auto /manual output mode by clicking "A/M" key(except"FY400").
Various Indication Lamps
Real time monitor the status of output (OUT1/OUT2), AT, alarm (AL1/AL2/AL3), manual output(MAN) and program(PRO)
Bar-Graph
Output percent displayed on the bar-graph in 10 LEDs resolution (except"FY400").
High Accuracy
Input with 14bit A/D resolution, 0.2% accuracy of FS. Built in "AutoZero- AutoSpan" function keep good accuracy.
RAMP & SOAK
Built in 1 segment of RAMP & SOAK function. Applicable on "SOFT" start condition.
Self-Diagnosis
Continuous checks the input status, RAM status and A/D status. When error was detected, the corresponding error code will be displayed on controller so that user can identify the source of trouble easily.
Data Lock Function
All parameters are seperated in 3 operation levels. Each parameter can be hidden or locked to prevent unauthorized changes.
(TC)
INPUT
Output
(Relay)
Voltage pulse (SSR drive)
(RTD)
(mA/V)
SCR/TRIAC Trigger
(mA/V/mV)
Motor Valve Control
Remote SV
PLC
Another controller
Input type : 0~20mA,4~20mA 0~5V,0~10V,2~10V,0~1V
Transmission
Recorder
Display
Signal type :PV,SV Output type: 0~20mA,4~20mA 0~5V,0~10V,2~10V,0~1V
Communication-RS485
(RS485 Communication)
Up to 31 controllers can be connected Max length 1200M
Communication-TTL
Up to 10 controllers can be connected Max length 1M
The SV vaiue of siave controllers will be remoted by master controller, and reached to max value at the same time
Ramp/Soak Program
There are 2 patterns by 8 segments can be used in ramp/soak program
There are 2 patterns can be linked togetter as 16 segments i ramp/soak program.
Heationg and Cooling Control
Motor Valve Control
SCR/TRIAC Trigger
■ Control Method
■ Fuzzy
■ Autotuning(AT)
■ Limit Setting
■ Easy Mounting
■ Saving Space
■ Alarm Types
■ Delay Time
■ Hold Function
Use this function can avoid alarm acts at shart-up.The alarm action is suppressed at start-up until PV enters the non-alarm range.