CHAUVIN ARNOUX CHAUVIN ARNOUX
ผู้เชี่ยวชาญด้านการวัดทางไฟฟ้า แบบพกพาและในห้องปฏิบัติการ
CHAUVIN ARNOUX F607 DIGITALE MULTIMETER
 |
CHAUVIN ARNOUX F607 DIGITALE MULTIMETER
Highlights:
AC and DC measurements
Power and energy measurements
Decomposition of harmonic orders
Measurement recorder
AC voltage (TRMS): from 0,15 to 1000V (1400 peak)
Automatic AC/DC survey: Yes
Autorange: Yes
Bandwidth V / A-W: from 10 Hz to 3 kHz / from 10 Hz to 1 kHz - 2000A
Clamping Ø: 60 mm
Current (TRMS) AC: from 0,15 to 2000A (3000A peak)
Current (TRMS) AC+DC: from 0,15 to 2000A (3000A peak)
Current (TRMS) DC: from 0,15 to 3000A
Diode test: Yes
Frequency: V: from 5 Hz to 20 kHz; I: from 5 Hz to 1 kHz
Measure: TRMS AC, DC, AC+DC
Power (single and three-phase): active, reactive, apparent, FP, DPF
Readout: Backlit LCD, 10000 counts
Resistence: from 0,1Ω to 100kΩ
Sound continuity: Yes
Voltage (TRMS) AC+DC: from 0,15 to 1000V (1400V)
Voltage (TRMS) DC: from 0,15 to 1400V
|
CHAUVIN ARNOUX F205 600 A TRMS AC+DC
.jpg) |
CHAUVIN ARNOUX F205 600 A TRMS AC+DC
Description:
The F205 clamp is ideal for low and medium-power Low-Voltage applications, maintenance of tertiary or industrial electrical installations and troubleshooting and sizing of electrical power supplies.
Equipped with a fast 12-bit TRMS digital acquisition system, F205 clamps offer particularly accurate measurements whatever the signal's type and waveform.
AC / DC voltage: from 0,15 to 1000 V
AC current: from 0,15 to 600 A (900 A peak)
AC/DC car survey: Yes
AC+DC current: from 0,15 to 600 A (900 A peak)
AC+DC voltage: from 0,15 to 1000 V
Accuracy: 1%L + 3 counts
Active Power: from 1 W to 600 kW
Apparent Power: from 1 VA to 600 kVA
Clamping Ø: 34 mm
DC current: from 0,15 to 900 A peak
Frequency: current: from 5,0 Hz to 3000 Hz / voltage: from 5,0 Hz to 20,00 kHz
Measure: TRMS (AC,AC+DC)/DC
Reactive Power: from 1 var to 600 kvar
Readout: LCD with backlight
Resistance / Voltage in open circuit: ≤ 8 V
Resolution: 6000 counts
|
CHAUVIN ARNOUX F203 600 A TRMS AC/DC
.jpg) |
CHAUVIN ARNOUX F203 600 A TRMS AC/DC
Description:
The F203 clamp is ideal for the needs of both self-employed electricians and SME contractors in the electrical sector.
Equipped with a fast 12-bit TRMS digital acquisition system, F203 clamps offer particularly accurate measurements whatever the signal's type and waveform.
AC / DC voltage: from 0,15 to 1000 V
AC current: from 0,15 to 600 A (900 A peak)
AC/DC car survey: Yes
Accuracy: 1%L + 3 counts
Clamping Ø: 34 mm
DC current: from 0,15 to 900 A peak
Frequency: current: from 5,0 Hz to 3000 Hz / voltage: from 5,0 Hz to 20,00 kHz
Measure: TRMS (AC)/DC
Other functions: True InRush, autorange, Hold, Min, Max, diode test, automatic shutdown
Power supply: 1 x 9V LF22
Readout: LCD with backlight
Resistance Voltage in open circuit: ≤ 8 V
Resolution: 6000 counts
Safety EN 61010: 600 V CAT IV
Sound continuity: Yes, adjustable from 1 to 599 Ω
Temperature (type K): from -60°C to 1000°C
|
CHAUVIN ARNOUX F201 600 A TRMS AC-MULTIMETER
.jpg) |
CHAUVIN ARNOUX F201 600 A TRMS AC-MULTIMETER
Description:
The F201 clamp is ideal for the needs of both self-employed electricians and SME contractors in the electrical sector.
Equipped with a fast 12-bit TRMS digital acquisition system, F201 clamps offer particularly accurate measurements whatever the signal's waveform.
AC / DC voltage: from 0,15 to 1000 V
AC current: from 0,15 to 600 A (900 A peak)
Accuracy: 1%L + 3 counts
Clamping Ø: 34 mm
Frequency: current: from 5,0 Hz to 3000 Hz / voltage: from 5,0 Hz to 20,00 kHz
Measure: TRMS (AC)
Other functions: True InRush, autorange, Hold, Min, Max, diode test, automatic shutdown
Power supply: 1 x 9V LF22
Readout: LCD
Resistance/Voltage in open circuit: ≤ 8 V
Resolution: 6000 counts
Safety EN 61010: 600 V CAT IV
Sound continuity: Yes, adjustable from 1 to 599 Ω
Temperature (type K): from -60°C to 1000°C
|
CHAUVIN ARNOUX F407 1000 A STROM
.jpg) |
CHAUVIN ARNOUX F407 1000 A STROM
Highlights:
AC and DC measurements
Measurements of power and energy values
Decomposition of harmonic orders
Measurement recorder
AC voltage (TRMS): from 0,15 to 1000V (1400V peak)
Automatic AC/DC survey: Yes
Autorange: Yes
Bandwidth V / A-W: from 10 Hz to 3 kHz / from 10 Hz to 2 kHz - 1000A
Clamping Ø: 48 mm
Current (TRMS) AC: from 0,15 to 1000A (1500A peak)
Current (TRMS) AC+DC: from 0,15 to 1000A (1500A peak)
Current (TRMS) DC: from 0,15 to 1500A
Diode test: Yes
Frequency: V: from 5 Hz to 20 kHz; I: from 5 Hz to 2 kHz
Harmonics: up to 25th and THD
Measure: TRMS AC, DC, AC+DC
Readout: Backlit LCD, 10000 counts
Resistence: from 0,1Ω to 100kΩ
Sound continuity: Yes
Voltage (TRMS) AC+DC: from 0,15 to 1000V (1400V peak)
Voltage (TRMS) DC: from 0,15 to 1400V
|
CHAUVIN ARNOUX F65 600A RMS AC-ABLEITSTROM
.jpg) |
CHAUVIN ARNOUX F65 600A RMS AC-ABLEITSTROM
Description:
In the event of an insulation fault or untimely tripping of RCDs, the F65 clamp is the ideal tool for detecting and measuring the leakage currents flowing to earth.
The versatile F65 clamp also offers all the functions of a multimeter clamp.
In addition, the F65 clamp is equipped with an RMS converter to ensure that the measurements remain accurate even in the presence of distorted signals.
Accuracy: 1,2 %
Current: mA AC
Electrical protection: 150 A RMS / 660 V RMS
Range Code: 60 / 600 mA AC
Readout: 10000 counts - 2 measures/s
Resolution: 10 μA / 100 μA
Sound continuity: Buzzer < 35 Ω
Tension: V AC / DC
|
CHAUVIN ARNOUX MX 350 TRMS KOMPAKT-MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 350 TRMS KOMPAKT-MULTIMETER
Description:
Equipped with all the essential functions (AC and DC voltage, AC current, resistance, frequency and continuity), the MX 350 clamp multimeter offers excellent handling and a particularly comfortable display.
It can be used to measure the frequencies of both the current (up to 10 kHz) and voltage (up to 100 kHz).
AC current: 40 / 400 A
AC voltage: 400 / 600 V
Accuracy: 1,9%L + 5D
Bar graph: Yes
Clamping Ø: 26 mm
DC voltage: 400 / 600 V
Frequency: I : 10 kHz / U : 1 MHz
Measures: AVG
Other functions: HOLD
Readout: 4000 counts
Resistence: 400 Ω
Safety EN 61010: Cat.III, 300 V / Cat.II, 600 V
Sound continuity: Yes
|
CHAUVIN ARNOUX MX 355 TRMS KOMPAKT-MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 355 TRMS KOMPAKT-MULTIMETER
Description:
Compact TRMS 400 A AC / DC clamp multimeter
Equipped with the essential functions (AC and DC voltage, AC and DC current, resistance and continuity), the MX 355 clamp multimeter offers excellent handling.
The versatile MX 355 clamp is the ideal companion for electricians working on the switchboard of a home or checking the power supply of a battery-powered system.
AC current: 40 / 400 A
AC voltage: 400 / 600 V
Accuracy: 1,5%L + 5D
Bar graph: Yes
Clamping Ø: 30 mm
DC current: 40 / 400 A
DC voltage: 400 / 600 V
Measures: AVG
Other functions: Δ-Zero / HOLD
Readout: 4000 counts
Resistence: 400 Ω
Safety EN 61011: Cat.III, 300 V / Cat.II, 600 V
Sound continuity: Yes
|
CHAUVIN ARNOUX MX 655 TRMS DIGITAL-MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 655 TRMS DIGITAL-MULTIMETER
Description:
Combining the basic functions of a multimeter and a Hall-effect current clamp for measuring DC and AC currents up to 1,000 A.
The use of an RMS converter ensures accurate measurements whatever the type or waveform of the signal.
It is extremely easy to grip and has a highly readable display.
AC current: 40 / 400 / 1000 A
AC voltage: 400 / 750 V
Accuracy: 1,9%L + 5D
Bar graph: Yes
Clamping Ø: 40 mm
DC current: 40 / 400 / 1000 A
DC voltage: 400 / 1000 V
Frequency: 4 kHz / 10 kHz
Measures: RMS
Readout: 4000 counts
Resistence: 400 Ω / 4 kΩ
Sound continuity: Yes
|
CHAUVIN ARNOUX MX 675 TRMS AC/DC DUAL-DISPLAY DIGITAL
.jpg) |
CHAUVIN ARNOUX MX 675 TRMS AC/DC DUAL-DISPLAY DIGITAL
Description:
The MX 675 combines the basic functions of an AC/DC multimeter and Hall-effect current clamp for measuring AC and DC currents up to 1,000 A.
Its 2 TRMS measurement channels enable it to display 2 values simultaneously on its large 10,000-count backlit display and the measurements are accurate whatever the waveform and type of the signal.
AC current: 100 / 1000 A
AC voltage: 1000 V
Accuracy: 1,5%L ± 5D
Clamping Ø: 40 mm
DC current: 100 / 1000 / 1400 A
DC voltage: 1000 / 1400 V
Frequency: 1 kHz / 10 kHz
Measures: TRMS
Readout: 10000 counts
Resistence: 1 kΩ / 10 kΩ
Sound continuity: Yes
Temperature: 1000 / 1200°C
|
CHAUVIN ARNOUX MX 355 TRMS KOMPAKT-MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 355 TRMS KOMPAKT-MULTIMETER
Description:
Compact TRMS 400 A AC / DC clamp multimeter
Equipped with the essential functions (AC and DC voltage, AC and DC current, resistance and continuity), the MX 355 clamp multimeter offers excellent handling.
The versatile MX 355 clamp is the ideal companion for electricians working on the switchboard of a home or checking the power supply of a battery-powered system.
AC current: 40 / 400 A
AC voltage: 400 / 600 V
Accuracy: 1,5%L + 5D
Bar graph: Yes
Clamping Ø: 30 mm
DC current: 40 / 400 A
DC voltage: 400 / 600 V
Measures: AVG
Other functions: Δ-Zero / HOLD
Readout: 4000 counts
Resistence: 400 Ω
Safety EN 61011: Cat.III, 300 V / Cat.II, 600 V
Sound continuity: Yes
|
CHAUVIN ARNOUX MX 650 DIGITALE MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 650 DIGITALE MULTIMETER
Description:
The MX 650 clamp combines the functions of an AC/DC multimeter and an AC current clamp up to 1,000 A.
It is extremely easy to grip with a highly readable display.
AC current: 40 / 400 / 1000 A
AC voltage: 400 / 750 V
Accuracy: 1,9%L + 5D
Bar graph: Yes
Clamping Ø: 36 mm
DC voltage: 400 / 1000 V
Frequency: 4 kHz / 10 kHz
Measures: AVG
Other functions: HOLD / PEAK / MIN / MAX / REL
Readout: 4000 counts
Resistence: 400 Ω / 4 kΩ
Safety EN 61012: Cat.III, 600 V
Sound continuity: Yes
|
CHAUVIN ARNOUX MX 670 TRMS AC/DC DIGITAL-MULTIMETER
.jpg) |
CHAUVIN ARNOUX MX 670 TRMS AC/DC DIGITAL-MULTIMETER
Description:
The MX 670 combines the basic functions of an AC/DC multimeter and an AC current clamp up to 1,000 A.
Its 2 TRMS measurement channels enable it to display 2 values simultaneously on its large 10,000-count backlit display and the measurements are accurate whatever the waveform and type of the signal.
AC current: 100 / 1000 A
AC voltage: 1000 V
Accuracy: 1,5%L ± 5D
Clamping Ø: 42 mm
DC voltage: 1000 / 1400 V
Frequency: 1 kHz / 10 kHz
Measures: RMS
Other functions: HOLD / Auto-HOLD / MIN / MAX / PEAK / Δ-Zero
Readout: 10000 counts
Resistence: 1 kΩ / 10 kΩ
Sound continuity: Yes
Temperature: 1000 / 1200°C
|
CHAUVIN ARNOUX C.A 702 DIGITALES TASCHENMULTIMETER
.jpg) |
CHAUVIN ARNOUX C.A 702 DIGITALES TASCHENMULTIMETER
With its compact design and built-in test probes, you can take the C.A702 with you everywhere you go.
Continuity test (buzzer) and diode test
Safety: IEC 61010 - 600V CAT IV / 1000V CAT III
AC and DC voltage: from 200mV to 600V
Resistence: from 200Ω to 20MΩ
|
CHAUVIN ARNOUX C.A 703 DIGITALES TASCHENMULTIMETER
.jpg) |
CHAUVIN ARNOUX C.A 703 DIGITALES TASCHENMULTIMETER
With its compact design and built-in test probes, you can take the C.A 703 with you everywhere you go.
Continuity test (buzzer) and diode test
Safety: IEC 61010 - 600 V CAT IV / 1000 V CAT III
AC and DC voltage: from 200mV to 600V
Current: from 200μA to 200mA
Resistence: from 200Ω to 20MΩ
|
CHAUVIN ARNOUX C.A 5011 ANALOGES/DIGITALES MULTIMETER
.jpg) |
CHAUVIN ARNOUX C.A 5011 ANALOGES/DIGITALES MULTIMETER
Description:
The C.A 5011TRMS multimeter gives the RMS value whatever the type of signal (sinusoidal or distorted).
This makes it ideal for all types of installations, even those involving "non-linear" loads..
AC current: 2x6 Ranges: from 400μA to 10A
AC voltage: 2x5 Ranges: from 400 mV to 1000 V
Accuracy (typical): -1,5% in V and 1% in A e Ω
Autonomy: 300 hours
Bandwidth: from 20 Hz to 10 kHz
Continuity sound test: for R < 400 Ω
dB-Scale in V: from -20 to +16 dB
DC current: 2x6 Ranges: from 400μA to 10A
DC voltage: 2x5 Ranges: from 400 mV to 1000 V
Electrical protection: Fuses 1 A and 10 A
Electrical safety: EN 61010-1 1000V CAT. III, 600V CAT. IV
Environmental conditions: from -10°C to +55°C and HR < 90%
Impedance: 10 MΩ
Power supply: 1 9V battery
Protection: IP 53
Readout: 4000 counts with backlight
Resistence: 6 Ranges: from 400 Ω to 40 MΩ
|
CHAUVIN ARNOUX C.A 5001 ANALOGES MULTIMETER
.jpg) |
CHAUVIN ARNOUX C.A 5001 ANALOGES MULTIMETER
Description.:
The C.A 5001 is a very competitively-priced analogue multimeter designed to meet all the needs of electricians.
AC current: 4 Ranges: from 50 mA to 5 A
AC voltage: 5 Ranges: from 10 V to 1000 V
Accuracy (typical): 1,5 % in VDC - 2,5 % in VAC and AAC - 10 % in Ω
Autonomy: 10 000 15-second measurements
Bandwidth: from 10 Hz to 100 kHz (depending on the range)
Continuity sound test: for R < 50 Ω
dB-Scale in AC voltage: from 0 to 22 dB
DC current: 5 Ranges: from 50 μA to 5 A
DC voltage: 8 Ranges: from 100 mV to 1000 V
Electrical protection: Fuses 0,5 A and 5 A Fuses 1,6 A and 16 A
Electrical safety: EN 61010-1 - 600 V/Cat III - 300 V/Cat IV
Impedance: 20 kΩ / V
Power supply: 1 1,5 V Battery
Protection: IP 40, IP 53
Resistence: 2 Ranges: 10 kΩ and 1 MΩ
|
CHAUVIN ARNOUX C.A 5003 ANALOGES MULTIMETER
.jpg) |
CHAUVIN ARNOUX C.A 5003 ANALOGES MULTIMETER
Description:
The C.A 5003 is a very competitively-priced analogue multimeter designedto meet all the needs of electricians.
AC current: 5 Ranges: from 1,5 mA to 15 A
AC voltage: 5 Ranges: from 10 V to 1000 V
Accuracy (typical): 1,5 % in VDC - 2,5 % in VAC and AAC - 10 % in Ω
Autonomy: 10 000 10-second measurements
Bandwidth: from 10 Hz to 100 kHz (depending on the range)
Continuity sound test: for R < 50 Ω
dB-Scale in AC voltage: from 0 to 22 dB
DC current: 7 Ranges: from 50 μA to 15 A
DC voltage: 8 Ranges: from 100 mV to 1000 V
Electrical protection: Fuses 0,5 A and 5 A Fuses 1,6 A and 16 A
Electrical safety: EN 61010-1 - 600 V/Cat III - 300 V/Cat IV
Environmental conditions: from -10°C to +55°C and HR < 90%
Impedance: 20 kΩ / V
Power supply: 9 V Battery
Protection: IP 40, IP 53
Resistence: 2 Ranges: 10 kΩ and 1 MΩ
|
CHAUVIN ARNOUX C.A 5005 ANALOGES MULTIMETER MIT STROMZANGE
.jpg) |
CHAUVIN ARNOUX C.A 5005 ANALOGES MULTIMETER MIT STROMZANGE
Description:
The C.A 5005 is a very competitively-priced analogue multimeter designed to meet all the needs of electricians.
It is delivered with a current clamp allowing measurement (with direct readings) of AC currents up to 200 A AC.
AC current: 5 Ranges: from 3 A to 300 A
AC voltage: 5 Ranges: from 10 V to 1000 V
Accuracy (typical): 1,5 % in VDC - 2,5 % in VAC and AAC - 10 % in Ω
Autonomy: 10 000 10-second measurements
Bandwidth: from 10 Hz to 100 kHz (depending on the range)
Continuity sound test: for R < 50 Ω
dB-Scale in AC voltage: from 0 to 22 dB
DC current: 6 Ranges: from 50 μA to 10 A
DC voltage: 8 Ranges: from 100 mV to 1000 V
Electrical safety: EN 61010-1 - 600 V/Cat III - 300 V/Cat IV
Environmental conditions: from -10°C to +55°C and HR < 90%
Impedance: 20 kΩ / V
Power supply: 9 V Battery
Protection: IP 40, IP 53
Resistence: 2 Ranges: 10 kΩ and 1 MΩ
|
CHAUVIN ARNOUX MX1 - ANALOG-MULTIMETER MX1
.jpg) |
CHAUVIN ARNOUX MX1 - ANALOG-MULTIMETER MX1
Description:
The MX 1 is an analog multimeter in an IP65 container with shockproof sheath.
Main features:
Accuracy / Impedance: 2% / 20kΩ / V.
AC voltage (6 ranges): from 5V to 1.500V.
Medium size.
Bandwidth: 16Hz to 1kHz.
DC current (7 ranges): from 50μA to 10A.
AC current (7 ranges): from 500μA to 10A.
Resistance (3 ranges): from 20kΩ to 2MΩ.
Continuity with beep sound.
Diode test.
dB: -6 to 66.
Dimensions: 155 x 98 x 40 mm.
Weight: 420 gr.
IP65 protection.
|
CHAUVIN ARNOUX MTX202 TRMS MULTIMETER
.jpg) |
CHAUVIN ARNOUX MTX202 TRMS MULTIMETER
Highlights:
Flexible three-phase current sensors
Measurements from .5 A to 3 kA
Battery life: 5 hours
IP67, 1, V CAT IV
Description:
Their compact casing fits in one hand and can be stowed in your toolbox for all your applications in the field.
With its magnetized sheath, the multimeter can be used hands-free, even in electrical cabinets.
The patented Multifix mounting system is ideal for use with these multimeters, allowing you to hook it onto a cabinet door or your belt or suspend it…
The two-position stand ensures easy reading however the multimeter is positioned.
Readings are made even clearer by the blue backlighting of the display (4,000 or 6,000 counts depending on the model).
The built-in torch means the multimeter can be used even in the dark.
The rotary switch offers one function per position.
On the front panel, 3 keys are all you need to access all the various functions.
The 600 V CAT III, IP54 double-well input terminals are easily accessible.
|
CHAUVIN ARNOUX MTX203 MULTIMETER
.jpg) |
CHAUVIN ARNOUX MTX203 MULTIMETER
Description:
Their compact casing fits in one hand and can be stowed in your toolbox for all your applications in the field.
With its magnetized sheath, the multimeter can be used hands-free, even in electrical cabinets.
The patented Multifix mounting system is ideal for use with these multimeters, allowing you to hook it onto a cabinet door or your belt or suspend it…
The two-position stand ensures easy reading however the multimeter is positioned.
Readings are made even clearer by the blue backlighting of the display 6,000 counts.
The built-in torch means the multimeter can be used even in the dark.
The rotary switch offers one function per position.
On the front panel, 3 keys are all you need to access all the various functions.
The 600 V CAT III, IP54 double-well input terminals are easily accessible.
Technical specifications:
Resistance : 1 Ω to 60 MΩ
Capacitance : 1 nF to 100 mF
Temperature with K thermocouple (°C / °F) : from -55 °C to +1 200 °C
Dimensions / weight: 170 x 80 x 50 mm / 320 g
AC voltage: from 0,6 V to 750 V
AC/DC current: from 10 μA to 10 A
DC voltage: from 0,6 V to 1000 V
Readout: 6.000 counts
|
CHAUVIN ARNOUX MTX204 MULTIMETER
.jpg) |
CHAUVIN ARNOUX MTX204 MULTIMETER
Description:
Their compact casing fits in one hand and can be stowed in your toolbox for all your applications in the field.
With its magnetized sheath, the multimeter can be used hands-free, even in electrical cabinets.
The patented Multifix mounting system is ideal for use with these multimeters, allowing you to hook it onto a cabinet door or your belt or suspend it…
The two-position stand ensures easy reading however the multimeter is positioned.
Readings are made even clearer by the blue backlighting of the display 6,000 counts.
The built-in torch means the multimeter can be used even in the dark.
The rotary switch offers one function per position.
On the front panel, 6 keys are all you need to access all the various functions.
The 600 V CAT III, IP54 double-well input terminals are easily accessible.
Electrical maintenance operations are optimized thanks to the VLowZ low-impedance voltage measurement function.
It is also very easy to carry out initial troubleshooting on PCBs by measuring the resistance, capacitance, diode, etc.
This means users can carry out:
• electrical maintenance
• initial troubleshooting on PCBs
• verification of radiator control, etc.
Technical specifications:
Resistance : 1 Ω to 60 MΩ
Capacitance : 1 nF to 100 mF
Temperature with K thermocouple (°C / °F) : from -55 °C to +1 200 °C
Dimensions / weight: 170 x 80 x 50 mm / 320 g
|
CHAUVIN ARNOUX INTEGRIERENDER SCHALLPEGELMESSER KLASSE 2 C.A 1310
.jpg) |
CHAUVIN ARNOUX INTEGRIERENDER SCHALLPEGELMESSER KLASSE 2 C.A 1310
Description:
The CA 1310 Class 2 integrating sound level meter compliant with the IEC 61672-1 standard is the ideal instrument for measuring the sound environment for a large number of applications :
Testing of noise exposure at work,
Testing of HVAC system noise
Building acoustics, neighbourhood noise disputes, etc.
Noise nuisance assessments, etc.
Equipped with a wide backlit screen with digital and bargraph display and time/date-stamping, the CA 1310 is easy to read in all circumstances.
Its ergonomic casing makes it simple to use: excellent grip, access to all the functions on the front panel, tripod insert, etc.
The microphone can be used remotely with a 5m extension cable, available as a n option.
Powered by normal or rechargeable batteries, it offers an excellent battery life of 60 hours! It can also be connected to the mains via its micro-USB port.
Measurements:
The CA 1310 offers 2 types of measurements: ‘instantaneous’ (SPL) or ‘equivalent continuous sound level’ (Leq).
For Leq measurements, the integration time can be set to periods from 10 seconds to 24 hours.
It can record up to 64,000 measurement points, with a sampling rate which can be set directly in the instrument's SETUP menu.
The PC software, SL-Software, allows you to monitor the measurements in real time, view the data and export them for analysis or measurement report generation.
The CA 1310 is delivered in a case with a foam wind-shield for outdoor measurements.
|
CHAUVIN ARNOUX C.A 833 KALIBRATOR FÜR SCHALLPEGELMESSER
.jpg) |
CHAUVIN ARNOUX C.A 833 KALIBRATOR FÜR SCHALLPEGELMESSER
Description:
The C.A 833 Calibrator is a standard source (1kHz) used for calibrating sound level meters.
Calibration level: 94 and 114 dB
|
CHAUVIN ARNOUX TACHOMETER C.A 1725
.jpg) |
CHAUVIN ARNOUX TACHOMETER C.A 1725
Description:
With its rotary switch, the CA 1725 is simple to use and offers numerous measurement possibilities with or without contact.
Measurement by photo-reflection for no-contact measurement: a reflective strip is positioned on the part to be tested.
Contact measurement with accessories: a mechanical adapter (cylinder, cone or calibrated wheel) converts the rotation speed into pulses which are then measured by the tachometer.
The digital display shows a 42-segment bargraph, the functions selected, the alarm thresholds, etc.
The rotary switch gives direct access to 7 different measurement units (RPM, Hz, etc.) and each key on the keyboard corresponds to a function (MIN MAX, Smoothing, alarms, etc.).
Autonomy: 250 measurements with a duration of 5 minutes each
Cyclical relationship: Range: from 10 to 10000% Resolution: from 0,1 to 1% Accuracy 0,1% (from 0,2 Hz to 50 Hz) 0,2% (from 50 Hz to 125 Hz) 1% (If > 125 Hz)
Environmental conditions: from -20 to +70 °C / relative humidity < 90%
Event counter: Measurement range: from 0 to 99999 Frequency range: from 0,1 Hz to 10 kHz (EXT) Accuracy ± 1 event
Hz function: Range: from 0,1 to 10000 Hz Resolution: from 0,0004 to 0,4 Accuracy 4.10-5 L ± 4 counts
Meters/minute function: Range: from 6 to 10000 m/min Resolution: from 0,0006 to 6 Accuracy 1.10-4 L ± 1 step
Ms function: Range: from 0,1 to 10000 ms Resolution: from 0,0003 to 0,3 Accuracy 1.10-4 L ± 5 counts
Power supply: 9V standard battery
Rear thread: tripod fixing
Rpm function: Range: from 60 to 100000 giri/min Resolution: from 0,0006 to 6 Accuracy 1.10-4 L ± 6 counts
|
CHAUVIN ARNOUX TACHOMETER C.A 1727
.jpg) |
CHAUVIN ARNOUX TACHOMETER C.A 1727
Description:
With its rotary switch, the CA 1727 is simple to use and offers numerous measurement possibilities with or without contact.
The CA 1727 is equipped with storage capacity and a USB interface so that the data can be processed with the Tachograph software (delivered as standard).
Measurement by photo-reflection for no-contact measurement: a reflective strip is positioned on the part to be tested.
Contact measurement with accessories: a mechanical adapter (cylinder, cone or calibrated wheel) converts the rotation speed into pulses which are then measured by the tachometer.
The digital display shows a 42-segment bargraph, the functions selected, the alarm thresholds, etc.
The rotary switch gives direct access to 7 different measurement units (RPM, Hz, etc.) and each key on the keyboard corresponds to a function (MIN MAX, Smoothing, alarms, etc.).
Autonomy: 250 measurements with a duration of 5 minutes each
Cyclical relationship: Range: from 10 to 10000% Resolution: from 0,1 to 1% Accuracy 0,1% (from 0,2 Hz to 50 Hz) 0,2% (from 50 Hz to 125 Hz) 1% (If > 125 Hz)
Environmental conditions: from -20 to +70 °C / relative humidity < 90%
Event counter: Measurement range: from 0 to 99999 Frequency range: from 0,1 Hz to 10 kHz (EXT) Accuracy ± 1 event
Hz function: Range: from 0,1 to 10000 Hz Resolution: from 0,0004 to 0,4 Accuracy 4.10-5 L ± 4 counts
Meters/minute function: Range: from 6 to 10000 m/min Resolution: from 0,0006 to 6 Accuracy 1.10-4 L ± 1 step
Ms function: Range: from 0,1 to 10000 ms Resolution: from 0,0003 to 0,3 Accuracy 1.10-4 L ± 5 counts
Power supply: 9V standard battery
Rear thread: tripod fixing
Rpm function: Range: from 60 to 100000 giri/min Resolution: from 0,0006 to 6 Accuracy 1.10-4 L ± 6 counts
|
CHAUVIN ARNOUX RPM82 - CONTACT TACHOMETER
.jpg) |
CHAUVIN ARNOUX RPM82 - CONTACT TACHOMETER
RPM82 contact tachometer.
Digital speedometer.
Operation with or without contact.
Accuracy: 0.05% + 1 point.
Rotation speed with contact: from 0.5 to 19,999 rpm.
Non-contact rotational speed: 2.5 to 99,999 rpm.
Sliding rotation speed: from 0.05 to 1,999.9 metres/min.
Automatic selection of courses.
Min, max, hold functions.
|
|